New products
Model Number: PD3060-PT100
Operating Temperature: -180 to +650
Supply Voltage: DC8-30V
Dissipation Power: 9mA
Model: PD3060-PT100
Can choose:OLED PT100/OLED PT1000/OLED CU50/OLED CU100/OLED NI1000.(default OLED PT100)
Measuring range: PT type sensor: temperature -180 ° C ~ +650 ° C, resolution 0.1 ° C;
CU100\50: -50 °C ~ +150 °C; NI1000:: -60 °C ~ +250 °C
1 Summary
Main characteristics
Be based on RS485 Interface,Modbus Temperature acquisition module.
Power supply, acquisition, communication three terminal isolation, standard MODUUS RTU protocol. All input interfaces have overvoltage protection.
SupportPT, Cu, NITemperature sensor two wire, three wire connection method.Three wire connection (the same as the three lead resistance) can completely eliminate the error caused by the lead resistance.
The sensing head can be up to 150 m without affecting the measured data.
The temperature calculation is completed in the module, and the temperature value can be read out directly.
Measuring range: PT type sensor: temperature-180℃+650℃, resolution 0.1℃;
CU100\50:-50℃~+150℃;NI1000::-60℃~+250℃
The accuracy can reach 0.25℃ at -20℃ to +150℃. The precision of other temperature range is better than 0.5℃.
Power supply: DC8-30V . Measured 30V power consumption 9mA, 24V power consumption 12mA, 12V power consumption 23mA, 8V power consumption 33mA.
Using standard35mmRail installation.
Outline dimension:88*72*59
Operating temperature -35℃~+50℃.
Applications: liquid and gas temperature measurement.
2 Commonly used product model images and interfaces
A:RS485 Serial communication A
B:RS485 Serial communication B
Power SupplyV+DC power supply
Power SupplyGNDDC power supply negative, common end
Three wire connection:
RTD (n) +Sensor supply side0.5mAOutput.
RTD (n) -Sensor input.
GNDSensor common end.
Two wire connection:
RTD (n) +Sensor supply side+Measuring input0.5mAOutput.
RTD (n) -Need andGNDShort connection.
GNDThe other end of the sensor.
3 registerInformation table and function code
Three point oneFunction code03H(read),06H(write)
parameterSet registerInformation table
3 registerInformation table and function code
|
Word address |
byte position |
describe |
Parameter description |
attribute |
|
10H |
low8position |
Communication configuration
Initial value:00H |
BIT<7>Parameter protection function= 0Close = 1open See note BIT<6:5> Retain BIT<4:3>00=No calibration 01=Even parity10=Odd parity check11=Odd parity check) BIT<2:0>000=9600 001=1200 010=2400 011=4800 100=9600 101=14400 110=19200Other combinations are not defined in accordance with9600Handle |
RW |
|
high8position |
Postal address Initial value:01H |
Setting range=1reachTwo hundred and fifty address0Broadcast address(If the value of the communication program is set0, equal to1) |
RW |
|
|
11H |
low8position |
Retain |
|
RW |
|
high8position |
Filter parameters Initial value:01H |
Setting range=1reach16;0Equivalent to1Greater than16Equivalent to16 When the value is relatively large, you can increase the appropriate filter parameters. This parameter isPTInvalid type module. |
RW |
|
|
12H |
16position |
Invalid flag value Initial value:-1000 |
Invalid flag value returned when sensor error,-1000Equivalent to temperature-100.This value can be redefined,See Appendix three |
RW |
Hardware information register information table
|
Word address |
byte position |
describe |
Parameter description |
attribute
|
|
16H ......... 1DH |
|
|
common8Unit,16individualBYTES. Is model information, such as:"PD3066-4W PT100","PD3065-K" "PD3064-J","PD3060 PT100" |
R |
Brand Name: NJouka
DIY Supplies: Plumbing
Model Number: TUF-2000M
Measurement Range: 15-100mm
TS2: 15-100mm
TUF-2000M TS-2Digital Ultrasonic Flowmeter Flow Meter Ultrasinic Flow Module/RTU with TS2 transducer (DN15-100mm) -30 ~ +90C
|
Features |
Description |
|
High accuracy |
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than +-1% |
|
Wide measuring range |
Several types transducer for selection, pipe size from DN15mm to DN6000mm |
|
Far transmission distance |
Connecting module and secondary meter through RS-485 interface, transmission distance up to 1000m |
|
Powerful Functions |
Current output: 4-20mA, one channel, can be used for flow/heat transmitter; OCT output: two channels, can be used for flow /heat switch; Current input: 4-20mA, three channels, can be used for data collector; Tri-wire resistance signal input (PT100): two channels, can be used for calorimeter. |
|
Wide Application |
Its unique features, particularly low cost, small size, high performance, local display, make it the ideal choice for industrial automation, processing control, flow meter networking, composing multi-channel, high accuracy flow meter. |
Structure of Unified Calorimeter:


Standard Packing List:
- Transmitter 1 set
- TM-1 type transducer 1 pair
- Clamp Fixture 1 set
- 5m×2 Transducer Cable 1 pair
- English User Manual 1 piece (electronic