RS485 Modbus RTU MP3 Player (Sound Module) DIN
Rated 3.5/5 based on 11 customer reviews

RS485 Modbus RTU MP3 Player (Sound Module) DIN

Voir tous les produits de : MultiShop.lu
Disponibilité : En stock
€146,88 €157,37

SPECIFICATIONS

Condition: New

Type: Voltage Regulator

Model Number: RS485 Modbus RTU MP3 Player

Application: Computer

is_customized: Yes

 

2017 New TNM5000 USB EPROM Programmer+18pc sockets+IC Clip for NAND flash/EPROM/MCU/PLD/FPGA/ISP/JTAG,Support K9GAG08U0E

 

 RS485 Modbus RTU operated MP3 player (sound module).

This module alows to play MP3 files placed on micro SD card via 2-wires RS485 line (up to 1200 meters long). Files can be called from PC, using USB-RS485 adapter as well as from different PLC /Smarthome/ Aumation controllers, working with Modbus RTU.

The device contains stereo line out audio jack and screw connectors so either headphones, active speakers or some sound mixing devices can be connected. 

 We send example/testing software along with this module. Saftware includes main functions that can be used with this module, showing Modbus RTU packet examples (in order user could set own smarthome/automation software to work with this player). 

All the commands are set by writing device registers (0x06 Modbus RTU function).

 

 

Short description of functions is below:

Register address

Command

Value range

0x0005

Play a file with name "___" placed in folder«MP3»

File name: «0001» ... «9999»  (up to 9999 files in total)

0x0006

Cyclically play all files from folder with name "___"

Folder name: «01» ... «99»    (up to 99 folders in total)

0x0007

Play file with name "___" from folder with name "___"

Folder name: «01» ... «15»

File name: «0001» ... «4095»

0x0008

Set volume

0…30

0x0009

Change volume by 1

0х01 – volume up, 0х02 – volume down

0x000A

Pause/ Continue play

0х00 – pause, 0х01 – continue

0x000B

Stop

0х00 – stop

0x000C

Equalizer

0x00-Normal, 0x01-Pop, 0x02-Rock, 0x03-Jazz, 0x04-Classic, 0x05-Bass

0x000D

Reset

0x00 - Reset

Device address and baudrate settings change EXAMPLE:

 

Current module address

Function code

Register address

New (needed) module address

New (needed) baudrate

CRC-16 Modbus checksum

0x01

0x06

0x00

0x00

0x05

0x02

0B

5B

Size: standard DIN rail 65 mm wide enclosure (89x70x65 mm).

Commands: standard Modbus RTU commands (write register) allow to play mp3 files from microSD card, change port baudrate, set module address.

Indication: 1 power on LED.

Data storage: micro SD memory card.

Power supply: 12V 100mA.

Memory: non-volatile memory chip for settings (module address and baudrate).

Connection: screw connectors for RS485, power supply, line out, USB connector for files upload, micro SD card connector, audio jack line out connector.

Modbus address: (can be changed by Modbus command) 0...255 (default address: 0x01).

Baudrate: (can be changed by Modbus command) 2400, 4800, 9600, 19200, 28800, 38400, 56000, 57600, 115200, 128000, 256000 (default is 9600).

Port settings: 8n1

Manual and testing software: will be sent along with the module

SPECIFICATIONS

Condition: New

Type: Voltage Regulator

Model Number: RS485 Modbus RTU MP3 Player

Application: Computer

is_customized: Yes

 

2017 New TNM5000 USB EPROM Programmer+18pc sockets+IC Clip for NAND flash/EPROM/MCU/PLD/FPGA/ISP/JTAG,Support K9GAG08U0E

 

 RS485 Modbus RTU operated MP3 player (sound module).

This module alows to play MP3 files placed on micro SD card via 2-wires RS485 line (up to 1200 meters long). Files can be called from PC, using USB-RS485 adapter as well as from different PLC /Smarthome/ Aumation controllers, working with Modbus RTU.

The device contains stereo line out audio jack and screw connectors so either headphones, active speakers or some sound mixing devices can be connected. 

 We send example/testing software along with this module. Saftware includes main functions that can be used with this module, showing Modbus RTU packet examples (in order user could set own smarthome/automation software to work with this player). 

All the commands are set by writing device registers (0x06 Modbus RTU function).

 

 

Short description of functions is below:

Register address

Command

Value range

0x0005

Play a file with name "___" placed in folder«MP3»

File name: «0001» ... «9999»  (up to 9999 files in total)

0x0006

Cyclically play all files from folder with name "___"

Folder name: «01» ... «99»    (up to 99 folders in total)

0x0007

Play file with name "___" from folder with name "___"

Folder name: «01» ... «15»

File name: «0001» ... «4095»

0x0008

Set volume

0…30

0x0009

Change volume by 1

0х01 – volume up, 0х02 – volume down

0x000A

Pause/ Continue play

0х00 – pause, 0х01 – continue

0x000B

Stop

0х00 – stop

0x000C

Equalizer

0x00-Normal, 0x01-Pop, 0x02-Rock, 0x03-Jazz, 0x04-Classic, 0x05-Bass

0x000D

Reset

0x00 - Reset

Device address and baudrate settings change EXAMPLE:

 

Current module address

Function code

Register address

New (needed) module address

New (needed) baudrate

CRC-16 Modbus checksum

0x01

0x06

0x00

0x00

0x05

0x02

0B

5B

Size: standard DIN rail 65 mm wide enclosure (89x70x65 mm).

Commands: standard Modbus RTU commands (write register) allow to play mp3 files from microSD card, change port baudrate, set module address.

Indication: 1 power on LED.

Data storage: micro SD memory card.

Power supply: 12V 100mA.

Memory: non-volatile memory chip for settings (module address and baudrate).

Connection: screw connectors for RS485, power supply, line out, USB connector for files upload, micro SD card connector, audio jack line out connector.

Modbus address: (can be changed by Modbus command) 0...255 (default address: 0x01).

Baudrate: (can be changed by Modbus command) 2400, 4800, 9600, 19200, 28800, 38400, 56000, 57600, 115200, 128000, 256000 (default is 9600).

Port settings: 8n1

Manual and testing software: will be sent along with the module